    • The entire building or its major part with at least one wheelchair access is accessible. Visit is possible without any prior arrangements.
    • Ramps (portable and fixed) in front of entrances and inside the buildings have the maximum slope of 12.5% for lengths of up to 3 metres or 8% for lengths of up to 9 metres. The minimum width of fixed ramps is 110 cm.
    • Doors and passages are at least 80 cm wide, which also applies to the entrance (main) wing of double-wing doors. The doorsill height is no more than 2 cm.
    • A self-service elevator is available for overcoming any elevation and the minimum dimensions are as follows: door width of 80 cm, inner dimensions of the cabin: width 100 cm x depth 125 cm. Buildings with a platform are not classified as accessible buildings.
    • In the case of buildings with public toilets, WC I toilet is wheelchair accessible, or at least partially accessible WC II toilet is available, providing all other accessibility criteria are met.
    • Surfaces and slopes of roads and paths inside the building and in its immediate surroundings do not pose any major complication for wheelchair users.

29.9.2020 10:40:25 - updated 3.11.2020 13:38:12 | read 241x | ruzickova | Full article
 

Partially accessible buildings

Částečně přístupné objekty
    • Only a part of the building is accessible, or the building does not meet any of the requirements listed for accessible buildings. Description of the requirements that are not met is provided in the text.

    • Ramps and skids (mobile and portable) in front of entrances and inside the buildings have the maximum slope of 16.5% for lengths of up to 3 metres, or 12.5% for lengths of up to 9 metres. The minimum width of fixed ramps is 100 cm.

    • Doors and passages are at least 70 cm wide. The doorsill height is no more than 7 cm.

    • Minimum elevator dimensions: door width of 70 cm, inner dimensions of the cabin: width 90 cm x depth 110 cm.

    • Minimum platform dimensions: door width 70 cm, transporting area: width 70 cm x depth 90 cm. Information about load bearing capacity is provided in the accompanying text.

    • Accessible toilets are not an essential factor. Owing to the current level of access in the Czech Republic, the requirement of at least WC II in partially accessible buildings would mean classifying a major part of buildings as inaccessible.
    • No more than one step without any appropriate compensation is in front of the entrance to the building.

29.9.2020 10:52:10 - updated 16.10.2020 15:51:26 | read 355x | ruzickova | Full article
 

Buildings with difficult or no access

Objekt obtížně přístupný nebo nepřístupný, author: Pražská organizace vozíčkářů, o. s.

  • The access to or movement around the building is especially complicated (combination of numerous reasons)